How every number on WattCost is calculated. The calculation engine is open, deterministic and covered by automated tests for every formula below.
The core formula
Running cost = energy used (kWh) × price per kWh. Energy comes from the appliance's official figure where one exists; the price comes from the latest published household tariff for your area.
- Power-based (TVs, monitors, heaters, fans): kWh = watts × hours ÷ 1,000, plus standby watts × the remaining hours. Example: 1,200 W × 3 h × 26.32p/kWh = 94.8p a day.
- Per cycle or per use (washers, dishwashers, dryers, ovens, air fryers): kWh per cycle × cycles per week × 52.18 weeks.
- Official annual figure (fridges, room air conditioners, dehumidifiers…): the label's kWh/year, which you can scale up or down from 25% to 300% to match how you use it. Each model page states the label's own assumption (e.g. Australian TV labels assume 10 hours a day; US TV labels 5 hours).
Per day = per year ÷ 365.25; per week = per year ÷ 52.18; per month = per year ÷ 12; 5- and 10-year totals are simple multiples at today's price (no inflation assumed).
Which price we use
- The tariff in force today for the area: the latest period whose start date has passed. Future periods (e.g. Ontario's 1 November prices) switch in automatically on their start date.
- If an area has no price of its own we fall back to the national figure, label it clearly and do not index that page.
- Average prices (EIA, Eurostat, MBIE, ElCom): published as average revenue per kWh, they already spread fixed charges across consumption.
- Unit rate + standing charge (Ofgem price cap, Australian default offers, utility tariffs): we use the unit rate for appliance costs and show the standing charge separately, because you pay it whether or not the appliance runs.
- Tiered (block) tariffs (Hydro-Québec, BC Hydro, DEWA, TEPCO, Ontario tiered): marginal mode prices only the extra kWh the appliance adds on top of the rest of your household's use; average mode spreads the whole bill's energy cost over every kWh. Daily thresholds are converted to months at 30.44 days. Without your household's use, the appliance is priced from the first block.
- Time-of-use: choose the band the appliance runs in; otherwise the bands are averaged with equal weight.
- Taxes: most sources include VAT/GST. Where a published price excludes tax and the rate is unambiguous we add it (Québec GST + QST 14.975%, BC and Alberta GST 5%, Dubai VAT 5%); otherwise the page says the price excludes sales tax. From 1 October 2026 to 31 March 2027 GB domestic electricity carries no VAT (Ofgem).
- Surcharges charged per kWh (DEWA fuel surcharge, Japan's renewable-energy surcharge) are added to the rate.
- You can always type the unit rate from your own bill; it replaces the published price.
Category estimates and default usage
When you haven't picked a model, appliances with registry data use the median model of that registry in your market. Other appliances use the typical power ratings below, always labelled “category estimate”. In the US and Canada, plug-in heaters, kettles and hair dryers default to 1,500 W because standard 120 V outlets limit them.
Electric cars
Cost = distance × official consumption × (1 + extra losses) × price. US figures are the EPA label's combined kWh/100 miles (FuelEconomy.gov); EU figures are WLTP electric energy consumption from the EEA's new-car registrations. Both are measured at the wall, so normal charging losses are already included — the default extra loss is 0%, and you can add some for cold weather, motorway driving or slow 120 V charging. The default distance (10,000 miles or 15,000 km a year) is a round number, not a national average.
EU figures are aggregated per make and commercial name: the registration-weighted median of WLTP Wh/km, discarding values outside 90–400 Wh/km (some countries report placeholder or wrongly scaled values), and publishing only models with at least 50 registrations. The 10th–90th percentile range is shown on each page. Outside the US and EU we show the same vehicles “based on US/EU test data”.
Heat pump vs gas boiler
For the same heat demand: heat-pump electricity = heat ÷ SCOP; boiler gas = heat ÷ efficiency; plug-in heaters use 1 kWh of electricity per kWh of heat. Defaults: SCOP 2.8 (Energy Systems Catapult, Electrification of Heat demonstration (median air-source heat pump SPF H4 2.80, 16 March 2023)) and boiler efficiency 86% (Commission Regulation (EU) No 813/2013 — minimum 86% seasonal space-heating efficiency for gas boilers). Heat-pump model pages show the official SEER2/HSPF2 ratings; annual consumption depends on your home and climate, so it is never presented as an official figure.
Replace or keep, and lifetime cost
Annual saving = (old kWh − new kWh) × price. Payback years = purchase price ÷ annual saving, interpolated within the year, with an optional annual price change you choose. Lifetime cost = purchase price + kWh/year × price × years.
Rounding
Calculations keep full precision; money is rounded once for display to the currency's smallest unit (half away from zero). Amounts under one unit are shown in cents, pence, fils or Rappen so per-hour costs stay readable.
Limits
- Official figures come from standardised laboratory tests. Real use varies with settings, climate, load and age.
- Average prices hide differences between suppliers and plans; enter your own rate for an exact figure.
- These are estimates, not a bill. See the disclaimer.